Automating Fixed Plate and Magnetic Steel Assembly in High-Voltage DC Relays
This assembly process mates ferromagnetic fixed plates and permanent magnetic steel to form the magnetic circuit core of high-voltage DC relays. The primary failure modes are magnetic polarity reversal, inconsistent air gap, and ferromagnetic debris contamination. Dedicated special machines implement constrained feeding, polarity validation, guided staking and ionized air shielding to stabilize Cpk ≥ 1.33 on mass production lines.
FAQ
Fixed Plate Installation Machine
Model changeover completes within 45 minutes. It requires swapping escapement inserts, updating polarity threshold parameters and running 10-piece first article validation.
Pneumatic valves, sensors and servo drives use mainstream Panasonic and SMC standard parts. Spare part lead time is 2–4 weeks for most overseas markets.
FAT acceptance requires Cpk ≥1.33 on 125 consecutive samples. SAT repeats the same Cpk test after on-site installation.
The machine meets ISO 13849 PLd safety requirements. Hard guards and safety interlocks prevent accidental access during high-speed feeding and pressing cycles.
Actuator Comparison Table for Magnetic Circuit Assembly
| Parameter | Pneumatic Press | Servo Electric Cylinder Press |
|---|---|---|
| Repeatability | ±0.08 mm | ±0.02 mm |
| Max Thrust | 2500 N | 1200 N |
| Stroke Velocity | Fixed | Adjustable closed-loop |
| Maintenance Interval | 20,000 cycles | 100,000 cycles |
| Relative Capex | Low | Medium |